Site icon Epomedicine

Schirmer’s test

Schirmer’s test is a measurement of tear production, devised by the German ophthalmologist Otto W.A. Schirmer. Originally, Schirmer used blotting paper to collect tears elicited by one of the 3 methods of stimulating lacrimation:

  1. Inserting the strip of paper itself
  2. Irritating the nasal mucosa after the cornea had been anesthetized
  3. Having the patient look into the sun

Indication: Evaluation of dry eye (Measures aqueous tear production)

Mnemonic:

Test 1 measures 2 things.
Test 2 measures 1 thing.
Test 3 measures Nose thing.

Types:

1. Schirmer I (without anesthetic): measures baseline and reflex tear secretion

2. Schirmer II (with anesthetic): measures baseline secretion

3. Schirmer III (without anesthetic): with nasal irritation

According to some authors: Schirmer I is divided into a. without anesthetic and b. with anesthetic. While Schirmer II represents test with nasal irritation.

Materials required: 5 X 35 mm of Schirmer’s strip or Whatman filter paper no. 41

Procedure:

  1. The eye is gently dried of excess tears
  2. The schirmer strip is folded 5 mm from one end and kept in the lower fornix at the junction of lateral 1/3 and medial 2/3 (do not touch cornea or lashes)
  3. The patient is asked to close the eyes.
  4. Tears in the conjunctival sac will cause progressive wetting of the paper strip.
  5. After 5 minutes, the filter paper is removed and the distance between the leading edge of wetness and the initial fold is measured, using a millimeter ruler.

Interpretation:

Normal: >15 mm

Mild-moderate Keratoconjunctivitis sicca (KCS): 5-10 mm

Severe KCS: <5 mm

<10 mm is considered abnormal in Schirmer 1 and <5 mm in Schirmer 2

Causes of KCS:

  1. Idiopathic
  2. Congenial alacimia
  3. Xerophthalmia
  4. Lacrimal gland ablation
  5. Sensory denervation
  6. Collagen vascular disease: Sjogren syndrome, SLE, RA
Exit mobile version